Limits Management Hardware - DCVS The LMH-DCVS block is a hardware IP for every CPU cluster, to handle quick changes in thermal limits. The hardware responds to thermal variation amongst the CPUs in the cluster by requesting limits on the clock frequency and voltage on the OSM hardware. The LMH DCVS driver exports a virtual sensor that can be used to set the thermal limits on the hardware. LMH DCVS driver can be a platform CPU Cooling device, which registers with the CPU cooling device interface. All CPU device nodes should reference the corresponding LMH DCVS hardware in device tree. CPUs referencing the same LMH DCVS node will be associated with the corresponding cooling device as related CPUs. Properties: - compatible: Usage: required Value type: Definition: shall be "qcom,msm-hw-limits" - interrupts: Usage: required Value type: Definition: Should specify interrupt information about the debug interrupt generated by the LMH DCVSh hardware. LMH DCVSh hardware will generate this interrupt whenever it makes a new cpu DCVS decision. - qcom,affinity: Usage: Required Value type: Definition: Should specify the cluster affinity this hardware corresponds to. - isens_vref_1p8-supply: - isens_vref_0p8-supply: Usage: optional Value type: Definition: Should specify the phandle of the vref regulator used by the isens hardware. This active only regulator will be enabled by LMH DCVSh. Isens hardware needs 1.8v and 0.8v supply regulators. - isens-vref-1p8-settings: - isens-vref-0p8-settings: Usage: optional Value type: Definition: Should specify the min voltage(uV), max voltage(uV) and max load(uA) for the isens vref regulator. This property is valid only if there is valid entry for isens_vref_1p8-supply and isens_vref_0p8-supply. - reg: Usage: Required Value type: Definition: where 'a' is the starting register address of the OSM/LLM and 'b' is the size of OSM/LLM address space. The register space in index 0 should be LLM and index 1 should be OSM. - qcom,plat-mitigation-disable: Usage: optional Value type: Definition: Should define this property if platform based cpu cooling device is not required. Example: lmh_dcvs0: qcom,limits-dcvs@18350800 { compatible = "qcom,msm-hw-limits"; interrupts = ; qcom,affinity = <0>; isens_vref_1p8-supply = <&pm8998_l1_ao>; isens-vref-1p8-settings = <880000 880000 36000>; isens_vref_0p8-supply = <&pm8998_l12_ao>; isens-vref-0p8-settings = <880000 880000 36000>; reg = <0x18350800 0x1000>, //LLM <0x18323000 0x1000>; //OSM qcom,plat-mitigation-disable; }; CPU0: cpu@0 { device_type = "cpu"; compatible = "arm,armv8"; reg = <0x0 0x0>; qcom,lmh-dcvs = <&lmh_dcvs0>;; };